Built for long-term structural monitoring, the J200 Series LVDT features a spherical bearing mount that selfcompensates for angular misalignment, preventing side loads on the core rod. Guided core rod design, sealed metal housing, and double shielding ensure reliable performance in harsh outdoor conditions. Available in 20–500 mm strokes with AC (155°C) or DC (multiple output options) versions. Ideal for bridge deflection, building settlement, and dam deformation monitoring.
| Code | Stroke Range (mm) | Sensitivity mV/V/(mm) |
|---|---|---|
| HD-J200-200-XX | 20 | 50 |
| HD-J200-300-XX | 30 | 35 |
| HD-J200-500-XX | 50 | 20 |
| HD-J200-1000-XX | 100 | 10 |
| HD-J200-1500-XX | 150 | 8 |
| HD-J200-2000-XX | 200 | 6 |
| HD-J200-2500-XX | 250 | 4.8 |
| HD-J200-3000-XX | 300 | 4 |
| HD-J200-4000-XX | 400 | 3 |
| HD-J200-5000-XX | 500 | 2.4 |
All values are nominal unless otherwise noted. Dimensions are in mm unless otherwise noted.
FR: Full Range is the stroke range, end to end; FR= S for 0 to S stroke range.
FRO (Full Range Output): Algebraic difference in outputs measured at the ends of the range.
| Powers Supply AC | 3 V rms (1~7V rms Optional)@5KHz (400~10KHz Optional) |
| Powers Supply DC | 13-28VDC |
| Zero voltage | <20mV |
| Non-linearity (maximum) | <0.25% |
| Repeatability | <0.1% |
| Operating Temperature AC | -50℃~+155℃ |
| Operating Temperature DC | -20℃~+85℃ |
| TC of Sensitivity | <0.015%FS/℃ |
| Structure | Guided Core Rod |
| Wiring | Shielded Cable |
| Shock | 1000g@11 ms |
| Vibration | 20g@2000Hz |




WeChat