Need a direct replacement for imported 0.75" LVDTs? The HD‑HAR750 AC Series matches the standard 0.75" OD and PT02‑10‑6P connector for drop‑in compatibility with HR‑series models. Split‑core, rugged housing, and double shielding ensure reliable performance in harsh conditions. Available in 10 strokes from ±3 mm to ±254 mm, with axial or 90° outlet options. Ideal for turbines, hydraulic cylinders, test machines, and bridge monitoring.
| Code | Stroke Range (mm) | Sensitivity mV/V/(mm) |
|---|---|---|
| HD-HAR750-125-X-AC | ±3 | 158 |
| HD-HAR750-250-X-AC | ±6.35 | 98 |
| HD-HAR750-500-X-AC | ±12.7 | 25 |
| HD-HAR750-1000-X-AC | ±25.4 | 24 |
| HD-HAR750-2000-X-AC | ±50.8 | 16 |
| HD-HAR750-3000-X-AC | ±76.2 | 10 |
| HD-HAR750-4000-X-AC | ±101.6 | 7 |
| HD-HAR750-5000-X-AC | ±127 | 4.7 |
| HD-HAR750-7500-X-AC | ±190.5 | 4.3 |
| HD-HAR750-10000-X-AC | ±254 | 3.1 |
All values are nominal unless otherwise noted. Dimensions are in mm unless otherwise noted.
FR: Full Range is the stroke range, end to end; FR= S for 0 to S stroke range.
FRO (Full Range Output): Algebraic difference in outputs measured at the ends of the range.
| Powers Supply | 3 V rms (1~7V rms Optional) |
| Input Frequency | 2.5KHz (400~10KHz Optional) |
| Zero voltage | <20mV |
| Non-linearity (maximum) | <0.25% |
| Repeatability | <0.1% |
| Operating Temperature | -20℃~85℃ |
| TC of Sensitivity | <0.015%/℃ |
| Structure | Split Structure |
| Wiring | PT02-10-6P |
| Shock | 1000g@11 ms |
| Vibration | 20g@2000Hz |
| Displacement Cycle | >10⁶ cycles |