Designed where space and weight are critical, the HD‑095 AC Series is a 9.5 mm split‑body LVDT/LVRT with an ultra‑light core that adds minimal mass to the target. It fits tight spots like robot joints, miniature pumps, medical devices, and linear modules. Available in LVDT or LVRT, 0.3–50.8 mm strokes, and options up to 240°C—reliable feedback for high‑end motion systems.
| Code | Stroke Range (mm) | Sensitivity mV/V/(mm) |
|---|---|---|
| HD-095-003-X-AC | 0.3 | 124 |
| HD-095-005-X-AC | 0.5 | 129 |
| HD-095-013-X-AC | 1.3 | 172 |
| HD-095-025-X-AC | 2.5 | 100 |
| HD-095-030-X-AC | 3 | 100 |
| HD-095-050-X-AC | 5 | 94 |
| HD-095-127-X-AC | 12.7 | 68 |
| HD-095-200-X-AC | 20 | 45 |
| HD-095-254-X-AC | 25.4 | 67 |
| HD-095-300-X-AC | 30 | 30 |
| HD-095-508-X-AC | 50.8 | 27 |
All values are nominal unless otherwise noted. Dimensions are in mm unless otherwise noted.
FR: Full Range is the stroke range, end to end; FR= S for 0 to S stroke range.
FRO (Full Range Output): Algebraic difference in outputs measured at the ends of the range.
| Powers Supply | 3 V rms (1~7V rms Optional) |
| Input Frequency | 2.5KHz (2K~10KHz Optional) |
| Zero voltage | <20mV |
| Non-linearity (maximum) | <0.25% |
| Repeatability | <0.1% |
| Operating Temperature | Common type: -50℃~ +155℃ High temperature type: -50℃~ +240℃ |
| TC of Sensitivity | <0.01%FS/℃ |
| Structure | Split Structure |
| Wiring | 32AWG Teflon wire or shielded cable |
| Shock | 1000g@11 ms |
| Vibration | 20g@2000Hz |